INVERTER
 AC and DC input, AC output Power Supply
Uninterruptible Power Source

 

ACDC1200


Produces  AC Power from your DC source / Battery bank or AC source. Zero switch over time.
AC preferred option available, consult factory.

 

Behlman's  ACDC - INVERTERS delivers 1200 VA of 120 Vac, 60 Hz power

in a 5.25" high,19" rack mount chassis. The ACDC - INVERTER can cold start

(boot) on  AC or DC Input (48, or 125 VDC).  In the event of loss of AC input,

the ACDC - Inverter will automatically switch to your DC Battery in ZERO time.

The  INVERTER continuously conditions the incoming power, providing a high quality

sinewave output with very low distortion.

  


Features

  • 1200 VA in a 5.25" high chassis

  • Sinewave Output, Isolated and Floating

  • Cold Start on AC or DC Input

  • Automatic switch-over from AC to DC in ZERO time

  • AC, DC, Output and System failure monitoring via contact closure

  • In the event of Inverter failure, the unit will BYPASS to AC Input

 

  Click here for Printable Specifications Sheet.

SPECIFICATIONS

INPUT

MODELS 
ACDC1200-48
ACDC1200-125 
 or

 

Input AC Voltage for all Models

120 VAC +/- 10%, 1 phase
47-63 Hz

 

INPUT

48 VDC +/- 20%

125 VDC +/- 20%
  • AC service: 25Amps.

  • Maximum permissible voltage: 132VAC continuous.

  • DC switching voltage: 95VAC RMS.

  • Input Connections: Barrier strip on rear.

  • Quiescent DC current drain less than: 2Amps @ 48VDC,

  • 1Amp @ 125VDC.

  • Maximum DC burden (full load): 40Amps DC @ 38VDC, 15Amps DC @ 100VDC.

  • Output Connections: Four NEMA 5-15 receptacles.

AC operation with instantaneous automatic DC switch over (true on-line system) and cold start capability. (Start on AC or DC)

 

OUTPUT

Voltage:

120 VAC +/- 5%, 60 Hz, Isolated and floating.

Current:
10 Amps
Power:
1200VA
Waveform:
True on-line sine wave output
Power Factor:
100% of rated output into any power factor load.
Distortion:
Less than 3% THD typical
Switch Time:
Zero. True on-line
Efficiency:
80% typical
Connection:

Four NEMA 5-15 receptacles. Option: Barrier terminals.

 

PROTECTION CIRCUITS

Input:
Main circuit beaker.
Short Circuit Protection:
Short circuit overload electronically latches output to protect load.
Thermal Protection:
Internal temperature sensor prevents heat damage.
Bypass:

If the inverter fails the unit will route the AC input to the AC output. Bypass fuse on front panel, 15 Amps.

 

FRONT PANEL CONTROLS and INDICATORS

Power On/Off circuit breaker

Four LED's: AC PRESENT, DC PRESENT, AC OUTPUT and SYSTEM OK.

 

ALARM CONTACTS

Four contact closure:
NO AC; NO DC; NO AC OUT & SYSTEM FAIL.
Contact rating:
0.6 Amps @ 125VAC; 0.8Amps @ 110VDC; 2Amps @ 30VDC.
Connections:

Barrier strip on rear

 

MECHANICAL SPECIFICATIONS

Dimensions:
High strength 19"W Rack mounted chassis, 5.25"H x 19.00"D.
Weight:

65lbs.

 

ENVIRONMENTAL SPECIFICATIONS

Operating Temperature:
-200 to 550 C.
Humidity:
Up to 95% non-condensing
SWC:
Designed to meet IEEE C37.90.1.
Fast Transient:
Designed to meet IEEE C37.90.1.
EMI:
Designed for immunity to conducted & radiated EMI.
RFI:
Designed to meet IEEE C37.90.2 - 1997.

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa, Discover,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: Switching | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | New Products | Application Notes | Wild Frequency Information Center